Burwash Landing · potable water freeze protection

Can the well keep the water loop from freezing?

Calculating…

Your systemInputs marked yours are the loop details you gave: 250 m of 1½" poly pipe, 3" rigid insulation, 6 ft deep, 2.5 L/s constant flow, 0.9 °C well water, 4–5 draws of 8,000 L a day between 8 am and 6 pm on weekdays, kept between 0 and 10 °C. The well itself uses the ground data from the model page. Everything else is an assumption listed at the bottom.

Heat sources

Each option is checked against your loop over a full year, with the well loop's temperature simulated over its design life. Select a row to see its design week.

Heat sourcePeak heat it can addvs. your peakColdest waterElectricity / yrCost / yrStatus

Design week

Through the year

Soil temperature at pipe depth changes slowly through the year; the heat needed to warm each draw does not.

MonthAir °CSoil at pipe °CPipe heat loss WPump heat kWh/weekHeat added kWh/weekPeak kWColdest water °CWarmest water °C

What changes the answer

Heating setpoint

The water leaving the heat exchanger. Well water arrives at , so each extra degree adds about 10 kW during every draw.

Calculating…

Pump control between draws

Pump friction heat grows roughly with the cube of flow, so pump speed decides how warm the loop gets when nothing is drawn. Every option runs at full flow during draws. "Without added heat" shows whether the pump alone still keeps the loop above freezing if the heat source fails.

Calculating…

If the circulation pump stops

Heat can only reach the pipe while water moves, so no heat source protects stagnant water. Standing water in the coldest ground:

How it's calculated

Every formula with your current numbers. Soil, pipe and pump for ; the well check for the selected heat source.

Data sources and assumptions